CRYSOUND POCKET Acoustic Imaging Camera Now Available on Kickstarter.
CRYSOUND POCKET Acoustic lmaging Camera
Now Available on Kickstarter.
CRYSOUND POCKET Acoustic lmaging Camera
Now Available on Kickstarter.
Filter
Filter
Size of Preamplifier
Interface Type
Power Supply
Shop
This is where you can browse products in this store.
CRY5011 IEPE Analog In-IED
Channel 4
ADC Resolution 32 bit
Sampling Rate 10 Hz ~204.8 kHz, optional
CRY5085 Analog Output Class D 10W - ADD
Channel 2
Sampling Rate (48 / 96 / 192) kHz,Optional
DAC Resolution 32 bit
CRYSOUND POCKET Acoustic Imaging Camera
Mic Array 64 channels
Frequency 2k ~ 65k Hz
SPL 28 ~ 132 dB
CRY8125 Advanced Ex Acoustic Imaging Camera
Microphone Array 200 MEMS microphones
Frequency Range 2k - 100k Hz
SPL Range 28 - 132 dB
CRY8124 Advanced Acoustic Imaging Camera
Microphone array 200 channels MEMS microphone
Frequency range 2k - 100k Hz
SPL range 28 - 132 dB
CRY8500 Series SonoCam Pi Acoustic Camera
Mic Array 128, up to 208 channels
Beamforming Frequency 200 - 20k Hz (110cm array)
NAH Frequency 20 - 20k Hz (110cm array)
CRY2624 128-Mic Industrial Acoustic Imaging Camera (ATEX)
Microphone array 128 channels MEMS microphone
Effective test bandwidth 2kHz - 48kHz
Dynamic range 0.5dB - 12dB user adjustable
CRY2623 128-Mic Industrial Acoustic Imaging Camera
Microphone array 128 channels MEMS microphone
Effective test bandwidth 2kHz - 48kHz
Dynamic range 0.5dB - 12dB user adjustable
CRY2620 64-Mic Industrial Acoustic Imaging Camera
Microphone array 64 channels MEMS microphone
Effective test bandwidth 2kHz - 40kHz
Dynamic range 0.5dB - 12dB user adjustable
CRY2623M Fixed Acoustic Imaging Camera
Number of Microphone Channels 128 channels
Test Frequency Range 2kHz - 48kHz
Port RJ45
CRY2626G Drone-Mounted Acoustic Imaging Camera
Microphone array 128 channels MEMS microphone
Frequency range 2k - 48k Hz
SPL range 28 - 132 dB
CRY2851 Sound Level Meter
Microphone type CRY333
Open circuit Sensitivity 50mV/Pa(-26dB re 1 V/Pa)±2dB
Frequency range 3.15Hz~20kHz(±2dB)
CRY2833 Sound Level Meter
Operating Temperature Range -20~+60℃
Humidity Range ≤90% RH
Reference Level 94dB@1kHz/114dB@1kHz
CRY2834 Sound Level Meter
Microphone Type CRY331
Open Circuit Sensitivity 40mV/Pa(-28dB re 1 V/Pa)±1.5dB
Frequency Range 20Hz~12.5kHz(±2dB)
NA41 Set Noise Sensor Outdoor Wind & Rain Cover
Reference Incident Direction 90°
IP Protection Class IP65
Attenuation of Wind Noise >30dB@10m/s (Not damaged when wind speed reaches 30m/s)
NA43 Set Noise Sensor Outdoor Wind & Rain Cover
Reference Incident Direction 90°
IP Protection Class IP65
Attenuation of Wind Noise >30dB@10m/s (Not damaged when wind speed reaches 30m/s)
CRY2831 Sound Level Meter
Microphone Type CRY321
Open Circuit Sensitivity 25mV/Pa(-32dB re 1 V/Pa)±2dB
Frequency Range 20Hz~12.5kHz(±2dB)
CRY2110 Noise Sensor
Applicable standards IEC61672-2,GB/T3785-2
Measurement Range 25~130dBA (Related to the microphone)
Dynamic Range ≥110dB, without switch range
CRY2112 Noise Sensor
Applicable standards IEC61672-1, GB/T3785-1
Measurement Range 25~130dBA (Related to the microphone)
Dynamic Range ≥110dB, without switch range
CRY2301 Noise Sensor
Applicable standards IEC61672 class 1、GB/T3785 class 1
Measuring range 25~130dBA
Dynamic range >110dB
CRY2120 Noise Sensor
Applicable standards IEC61672-2, GB/T3785-2
Measurement Range 25~130dBA (Related to the microphone)
Dynamic Range ≥110dB, without switch range
CRY3213 NVH Measurement Microphone
Field Type Free-field
Sensitivity 50 mV/Pa, -26±2 dB re 1V/Pa
Frequency Response 3.15 Hz-20 kHz ±2 dB
CRY3203-S01 Free-Field Microphone Set, 1/2", 50mV/Pa
Field Type Free-field
Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 20kHz±2dB
CRY3203-S02 Free-Field Microphone Set, 1/2", 50mV/Pa
Field Type Free-field
Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 20kHz±2dB
CRY3261-S02 Free-Field Microphone Set, 1/2", 450mV/Pa
Field Type Free-field
Sensitivity 450 mV/Pa, -7 dB±2dB re 1V/Pa
Frequency Response 10 Hz to 16kHz ±2dB; 6 Hz to 20kHz ±3dB
CRY3101-S01 Free-Field Microphone Set, 1", 50mV/Pa
Field Type Free-field
Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 4Hz to 16kHz±2dB
CRY3201-S01 Free-Field Microphone Set, 1/2", 12.5mV/Pa
Field Type Free-field
Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 40kHz±2dB
CRY3401-S01 Free-Field Microphone Set, 1/4", 15.8mV/Pa
Field Type Free-field
Sensitivity 15.8mV/Pa, -36±1.5dB re 1V/Pa
Frequency Response 4Hz to 40kHz±2dB
CRY3403-S01 Free-Field Microphone Set, 1/4", 4mV/Pa
Field Type Free-field
Sensitivity 4mV/Pa, -48±3dB re 1V/Pa
Frequency Response 4Hz to 90kHz±2dB
CRY3403-S02 Free-Field Microphone Set, 1/4", 4mV/Pa
Field Type Free-field
Sensitivity 4mV/Pa, -48±3dB re 1V/Pa
Frequency Response 4Hz to 90kHz±2dB
CRY3102-S01 Pressure-Field Microphone Set, 1", 50mV/Pa
Field Type Pressure-field
Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 4Hz to 8kHz±2dB
CRY3202-S01 Pressure-Field Microphone Set, 1/2", 12.5mV/Pa
Field Type Pressure-field
Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 20kHz±2dB
CRY3202-S02 Pressure-Field Microphone Set, 1/2", 12.5mV/Pa
Field Type Pressure-field
Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 20kHz±2dB
CRY3204-S01 Pressure-Field Microphone Set, 1/2", 50mV/Pa
Field Type Pressure-field
Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 10kHz±2dB
CRY3402-S01 Pressure-Field Microphone Set, 1/4", 1.6mV/Pa
Field Type Pressure-field
Sensitivity 1.6mV/Pa, -56±3dB re 1V/Pa
Frequency Response 4Hz to 70kHz±2dB
CRY3402-S02 Pressure-Field Microphone Set, 1/4", 1.6mV/Pa
Field Type Pressure-field
Sensitivity 1.6mV/Pa, -56±3dB re 1V/Pa
Frequency Response 4Hz to 70kHz±2dB
CRY3404-S01 Pressure-Field Microphone Set, 1/4", 0.56mV/Pa
Field Type Pressure-field
Sensitivity 0.56mV/Pa, -65±3dB re 1V/Pa
Frequency Response 10Hz to 20kHz±2dB
CRY3406-S01 Pressure-Field Microphone Set, 1/4", 15.8mV/Pa
Field Type Pressure-field
Sensitivity 15.8mV/Pa, -36±1.5dB re 1V/Pa
Frequency Response 4Hz to 20kHz±2dB
CRY3203 Free-field Microphone, 1/2", Prepolarized, 50mV/Pa
Field Type Free-field
Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 20kHz±2dB
CRY3285 Free-field Microphone, 1/2",External-polarized, 50mV/Pa
Field Type Free-field
Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 20kHz±2dB
CRY3201 Free-field Microphone, 1/2", Prepolarized, 12.5mV/Pa
Field Type Free-field
Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 40kHz±2dB
CRY3281 Free-field Microphone, 1/2",External-polarized, 12.5mV/Pa
Field Type Free-field
Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 40kHz±2dB
CRY3403 Free-field Microphone, 1/4", Prepolarized, 4mV/Pa
Field Type Free-field
Sensitivity 4mV/Pa, -48±3dB re 1V/Pa
Frequency Response 4Hz to 90kHz±2dB
CRY578 Bluetooth LE Audio Interface
Bluetooth Version v5.4
Profile A2DP Source V1.3, AVRCP Target/Controller V1.6, HFP Hands Free/Audio Gateway V1.7, HSP Headset/Audio Gateway V1.2
Codec SBC, AAC, aptX, LDAC, LC3, mSBC, CVSD
CRY580 A²B Interface
Topology Single-master-multiple-slave linear topology
3.5mm Audio Interface Supports analog audio input/output
USB Interface Supports digital audio playback and recording
Anechoic Chamber
Cutoff frequency 80Hz
Background Noise -1.4dBA (ventilation closed),1.2dBA (ventilation open)
Free-field radius 1.8m@80Hz
CRY6151B Electroacoustic Analyzer
Quantity of Channels 4-channel input/output (scalable for synchronous 8-channel input/4-channel output)
Sample Rate All channels for simultaneous sampling at 44.1kHz - 192kHz, with 24-bit
Input Dynamic Range 115dB typical value
CRY6151 Electroacoustic Analyzer
Frequency Range 0.02~20kHz
Frequency Error <0.01%
Frequency band mode Customized at 0.02~20kHz
CRY3542 1/4" Preamplifier, IEPE, SMB Connector
Frequency Response Range 10Hz to 100kHz( ±0.2dB)
Input Impedance >2GΩ / 50pF
Output Impedance <50Ω
CRY3485 Free-field Microphone, 1/4", External-polarized, 4mV/Pa
Field Type Free-field
Sensitivity 4mV/Pa, -48±3dB re 1V/Pa
Frequency Response 4Hz to 90kHz±2dB
CRY3543 1/4" Preamplifier, IEPE, 10-32UNF Connector
Frequency Response Range 1Hz ~ 200kHz (±0.2 dB)
Input Impedance >28,0.4pF
Output Impedance <50Ω
CRY3401 Free-field Microphone, 1/4", Prepolarized, 15.8mV/Pa
Field Type Free-field
Sensitivity 15.8mV/Pa, -36±1.5dB re 1V/Pa
Frequency Response 4Hz to 40kHz±2dB
SonoLab Acoustic Analysis Software
Earphone ANC, ENC, SPKEQ, Background and current noise test, Hearing test, Functionality of earphone
Other Directional testing, Noise and vibration, Open-loop play and acquisition, Device calibration, Scan SN, Automated validation with limits, MES function, Automation, Data saving, Authorization, Sequence properties, Single-step test
Transmission method Customized communication, Wired connection, Bluetooth, HID, ADB, TCP/IP, Plug-in application, Serial ports
QuickRadio, Radio Frequency Analysis Software
BR(Basic Rate) TX power, Initial carrier frequency tolerance, Sensitivity-single slot packets, Modulation characteristic, Power control, Carrier frequency drift, Sensitivity-multi-slot packets, Maximum input level
EDR(Enhanced Data Rate) Relative TX power, Differential phase modulation, BER floor performance, Carrier frequency stability and modulation accuracy, Sensitivity, Maximum input level
Power consumption(optional) Current leakage, Charging current, Fully charged current, Power-on current, Shipping current
CRY3101 Free-field Microphone, 1", Prepolarized, 50mV/Pa
Field Type Free-field
Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 4Hz to 16kHz±2dB
CRY446 Accelerometer, Triaxial, 10mv/g, ±500g pk, 1Hz to 5kHz
Measuring Range (peak) ±500g pk
Sensitivity (25℃) 10mV/g(160Hz)
Frequency Response 1Hz to 5kHz(±1dB)
CRY438 IEPE Accelerometer, 1 Axis, 10mv/g, ±500g pk, 1Hz to 10kHz
Measuring Range (Peak) ±500g
Sensitivity (25℃) 10mV/g (160Hz)
Frequency Response 1Hz to 10kHz(±1dB); 0.6Hz to 20KHz(±3dB)
CRY573 Digital Microphone Converter
Mode PDM/I2S
Noise floor -95dB:A weighting;-92dB:Z weighting(20Hz-20kHz)
Dynamic range >90dB(1kHz,A-weighting)
CRY591L Bluetooth Switch Matrix
Dimension 104*120*42mm
Working band DC-18GHz
Working temperature -25℃~65℃
CRY592 Audio Filter
Quantity of channels (Differential or single-ended) 4
Frequency response ±0.1dB, 20Hz~20kHz
Insert Loss 0.05dB(typical value)
CRY445 Accelerometer, Triaxial, 100mv/g, ±80g pk, 1Hz to 4kHz
Measuring Range (peak) ±80g pk
Sensitivity (25℃) 100mV/g(160Hz)
Frequency Response 1Hz to 4kHz(±1dB); 0.5Hz to 8kHz(±3dB)
CRY710 Pneumatic Acoustic Test Chamber
Weight About 158kg
Outer dimension 1050(L)*700(W)*1090(H)mm
Inner dimension 320(L)*364(W)*295(H)mm
CRY3102 Pressure-field Microphone, 1", Prepolarized, 50mV/Pa
Field Type Pressure-field
Sensitivity 50mV/Pa,-26±1.5dB re 1V/Pa
Frequency Response 4Hz to 8kHz±2dB
CRY721C Pneumatic Acoustic Test Chamber
Color White
Weight About 155kg
Outer dimension 950(L)*700(W)*700(H)mm
CRY723 Pneumatic Acoustic Test Chamber
Color White
Weight About 78.5kg
Outer dimension 1380(L)*800(W)*1265(H)mm
CRY3202 Pressure-field Microphone, 1/2", Prepolarized, 12.5mV/Pa
Field Type Pressure-field
Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 20kHz±2dB
CRY443 Accelerometer, Triaxial, 50mv/g, ±100g pk, 1Hz to 4kHz
Measuring Range (peak) ±100g pk
Sensitivity (25℃) 50mV/g(160Hz)
Frequency Response 1Hz to 4kHz(±10%); 0.7Hz to 8kHz(±3dB)
CRY3204 Pressure-field Microphone, 1/2", Prepolarized, 50mV/Pa
Field Type Pressure-field
Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 10kHz±2dB
CRY723D Pneumatic Acoustic Test Chamber
Color White
Weight About 135kg
Box dimension 600(L)*550(W)*500(H)mm
CRY3284 Pressure-field Microphone, 1/2", External-polarized, 50mV/Pa
Field Type Pressure-field
Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 10kHz±2dB
CRY725 Pneumatic Acoustic Test Chamber
Color Beige
Weight About 340kg
Box dimension 800(L)*780(W)*715(H)mm
CRY725D Pneumatic Acoustic Test Chamber
Color Beige
Weight About 830kg
Outer dimension 860(L)*860(W)*1833(H)mm
CRY442 Accelerometer, Triaxial, 100mv/g, ±50g pk, 0.5Hz to 5kHz
Measuring Range (peak) ±50g pk
Sensitivity (25℃) 100mV/g(160Hz)
Frequency Response 0.5Hz to 5kHz(±1dB)
CRY441 Charge Accelerometer, 1 Axis, 5pC/g, ±2500g pk, 1Hz to 10kHz
Dynamic Specification ±2500g pk
Measuring Range (peak) 5pC/g(160Hz)
Sensitivity (25℃) 1Hz to 10kHz(±1dB)
CRY7865 Pneumatic Acoustic Test Chamber
Color White
Weight About 830Kg
Outer dimension 1530(L)*1280(W)*1750(H)mm
CRY437 Accelerometer, 1 Axis, 10mv/g, ±500g pk, 2Hz to 8kHz
Measuring Range (peak) ±500g pk
Sensitivity (25℃) 10mV/g(160Hz)
Frequency Response 2Hz to 8kHz(±1dB)
CRY7412 Ultra-Quiet Chamber
Color Porcelain white
Weight About 1.7ton
Outer dimension 1498(L)*1554(W)*1556(H)mm
CRY436 Accelerometer, 1 Axis, 100mv/g, ±50g pk, 1Hz to 12kHz
Measuring Range (peak) ±50g pk
Sensitivity (25℃) 100mV/g(160Hz)
Frequency Response 1Hz to 12kHz(±10%); 0.5Hz to 20kHz(±3dB)
CRY435 Accelerometer, 1 Axis, 100mv/g, ±50g pk, 1Hz to 6kHz
Dynamic Specification ±50g pk
Sensitivity (25℃) 100mV/g(160Hz)
Frequency Response 1Hz to 6kHz(±10%); 0.5Hz to10kHz(±3dB)
CRY3402 Pressure-field Microphone, 1/4" Prepolarized, 1.6mV/Pa
Field Type Pressure-field
Noominal Sensitivity 1.6mV/Pa, -56±3dB re 1V/Pa
Frequency Response 4Hz to 70kHz±2dB
CRY434 Accelerometer, 1 Axis, 100mv/g, ±50g pk, 0.5Hz to 8kHz
Measuring Range (peak) ±50g pk
Sensitivity (25℃) 100mV/g(160Hz)
Frequency Response 0.5Hz to 8kHz(±1dB)
CRY7413 Acoustic Test Chamber, Manual Door
Outer color Beige
Material Sheet metal
Outer dimension 820(L)*780(W)*730(H)mm
CRY433 Accelerometer, 1 Axis, 100mv/g, ±50g pk, 0.5Hz to 8kHz
Measuring Range (peak) ±50g pk
Measuring Range (peak) 100mV/g(160Hz)
Frequency Response 0.5 Hz to 8 kHz(±1 dB)
CRY432 Accelerometer, 1 Axis, 5mv/g, ±1000g pk, 1Hz to 12kHz
Measuring Range (Peak) ±1,000g pk
Sensitivity (25℃) 5mV/g(160Hz)
Frequency Response 1Hz to 12kHz(±1dB)
CRY431 IEPE Accelerometer, 1 Axis, 5mv/g, ±1000g pk, 1Hz to 12kHz
Measuring Range (Peak) ±1000g
Sensitivity (25℃) 5mV/g (160Hz)
Frequency Response 1Hz to 12kHz(±1dB)
CRY801B Headphone Test Fixture
Weight 2.6kg
Material Oxidized and blackened aluminum
Max-width 260mm
CRY575L Microphone Power Supply, Low-Noise
Frequency Response 10Hz to 60kHz (±0.5 dB)
Input impedance 1MΩ
Output impedance 100Ω
CRY802 ATF Hearing Protection Headphone Test Fixture
Weight 11.6kg
Material Oxidized and blackened aluminum
Max-width 156mm
CRY575 Microphone Power Supply
Frequency Response 10Hz to 60kHz±0.5dB
Input impedance 1MΩ
Output impedance 100Ω
CRY3611 Reference sound source
THD(25mmMRP) <1%,Typical<0.5%(200Hz to 10KHz)
Impedance 8 ohm±15%@350hz
Continuous Maximum Power 45W
CRY806 TWS Headphones Acoustic Test Fixture
Weight 1.42kg
Material Oxidized and blackened aluminum
Dimension(L*W*H) 256*210*255mm
CRY3482 Pressure-field Microphone, 1/4", External-polarized, 1.6mV/Pa
Field Type Pressure-field
Sensitivity 1.6mV/Pa, -56±3dB re 1V/Pa
Frequency Response 4Hz to 70kHz±2dB
CRY3605 Mouth Simulator, High-Performance ITU-T Rec.P51
Max Continuous Output SPL(25mmMRP) 110dB (200 Hz to 10 kHz) 100dB (100Hz to 10 kHz)
THD(94dBSPL, 25mmMRP) <0.8%, Typical: <0.5% (200 Hz to 10 kHz)
Frequency Response EQ: 94dB ±1 dB(100Hz to 10kHz)
CRY3603 Mouth Simulator 200Hz to 50k Hz, ITU-T Rec.P51
Max Continuous Output SPL (25mmMRP) 110dB (500Hz to 40 kHz) 94dB (200 Hz to 50 kHz)
THD(94dBSPL, 25mmMRP) <1.5%,Typical: <1.0% (1 kHz to 40 kHz)
Frequency Response EQ: 94dB ±1 dB(500Hz to 40kHz)
CRY5121 Programmable Battery Simulator
AC supply AC90-240V/50-60Hz
Input voltage PI1+/PI1-,PI2+/PI2- -30~+30V,-0.3~+30V
Input Current 4.096A
CRY584D Power Amplifier 20W
Quantity of channels 2
Connector for input and output BNC
Output Power 30W*2(load1.5Ω)
CRY3602 Mouth Simulator with Built-In 20dB Amplifier
Max Continuous Output SPL (25mmMRP) 110 dB(200 Hz to 10 kHz) 100 dB (100 Hz to 10 kHz)
THD(94dBSPL, 25mmMRP) <1.5% ,Typical: <1.0% (200 Hz to 10 KHz )
Frequency Response EQ:94dB ±1 dB(100Hz to 10kHz)
CRY5240 Programmable Battery Simulator
AC supply AC90-240V/50-60Hz
Input voltage:P+/P- -0.3~+26V
Input voltage of one channel:Vin1 9.9V
CRY3717-S01 Coupler Set
Nominal Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 100Hz to 8kHz±2dB
Dynamic Range 12dB to 134dB
CRY3719-S01 Coupler Set
Nominal Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 125Hz to 8kHz
Dynamic Range 23dB to 146dB
CRY3406 , Pressure-field Microphone, 1/4" Prepolarized, 15.8mV/Pa
Field Type Pressure-field
Sensitivity 15.8mV/Pa, -36dB±1.5dB re 1V/Pa
Frequency Response 4Hz to 20kHz±2dB
CRY3404 Pressure-field Microphone, 1/4", Prepolarized, 0.56mV/Pa
Field Type Pressure-field
Sensitivity 0.56mV/Pa, -65±3dB re 1V/Pa
Frequency Response 10Hz to 20kHz±2dB
CRY3282 Pressure-field Microphone, 1/2", External-polarized, 12.5mV/Pa
Field Type Pressure-field
Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 3.15Hz to 20kHz±2dB
CRY3721-S01 Ear Simulator Set
Nominal Sensitivity 354 mV/Pa,-9 dB re 1V/Pa
Frequency Response 20 Hz to 20 kHz
Dynamic Range 7.5dBA to 115dB
CRY3501 1/2" Preamplifier, IEPE, BNC Connector
Frequency Response Range 1Hz ~ 200kHz (±0.2 dB)
Input Impedance >6,0.4pF
Output Impedance <50Ω
CRY3711-S01 Ear Simulator Set
Nominal Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 100Hz to 10kHz ±1dB(Simulated human ear impedance)、 20Hz to 16kHz(Coupling cavity use)
Dynamic Range 23dB to 146dB
CRY3718-S01 Ear Simulator Set IEC60318-1
Nominal Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 100Hz to 10kHz ±1dB(Simulated human ear impedance)、 20Hz to 16kHz(Coupling cavity use)
Standards IEC 60318-1、 ITU-T P.57 Type 1
CRY3717 IEC 60318-3 Coupler
Frequency Response 100Hz to 8kHz±2dB
Standards IEC60318-3
Equivalent Volume 6cc
CRY3521 1/2" Preamplifier, BNC connector, Base-type
Frequency Response Range 20Hz to 50k Hz (±0.2 d B); 10Hz to 100k Hz (±0.5 d B)
Input Impedance >2GΩ/0.5pF
Output Impedance <20Ω
CRY3719 Coupler IEC 60318-5
Frequency Response 125Hz to 8kHz
Equivalent Volume 2cc
Standards IEC60318-5, ANSI S3.7、 GB/T 20441.4-2006
CRY3711 Ear Simulator IEC60318-4
Nominal Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 100Hz to 10kHz ±1dB(Simulated human ear impedance)、 20Hzto 16kHz(Coupling cavity use)
Dynamic Range 23dB to 160dB
CRY3721 Ear Simulator IEC60318-4, Low-Noise
Standards IEC 60318-4, ITU-T P.57 Type 2
Equivalent Volume 1.26cc
Weight 50g
CRY3502 1/2" Preamplifier, IEPE, SMB Connector, Very Short
Frequency Response Range 1Hz ~ 200kHz (±0.2 dB)
Input Impedance >26,0.4pF
Output Impedance <50Ω
CRY3503 1/2" Preamplifier, IEPE, Microdot Connector, Very Short
Frequency Response Range 1Hz ~ 200kHz (±0.2 dB)
Input Impedance >26,0.4pF
Output Impedance <50Ω
CRY3541 1/4" Preamplifier, IEPE, SMB Connector
Frequency Response Range 1Hz ~ 200kHz (±0.2 dB)
Input Impedance >28,0.4pF
Output Impedance <50Ω
CRY3018 Sound Calibrator
Frequencies 1000 Hz, 250 Hz
Frequency Accuracy < 0.5 Hz
Sound Pressure Levels (SPL) 94 dB / 114 dB
CRY563B 1" Sound Calibrator
Calibrated Sound Pressure 94dB / 114dB
Calibration Accuracy ±0.2dB(+23℃; ±0.3dB(-10℃ to +50℃)
Calibration Frequency 1kHz±1%
CRY563A 1/2" Sound Calibrator
Calibrated Sound Pressure 94dB / 114dB
Calibration Accuracy ±0.2dB(+23℃; ±0.3dB(-10℃ to +50℃)
Calibration Frequency 1kHz±1%
CRY3718 Ear Simulator IEC60318-1
Frequency Response 100Hz to 4kHz ±1dB(Simulated human ear impedance)、 20Hz to 16kHz(Coupling cavity use)
Standards IEC 60318-1、 ITU-T P.57 Type 1、 GB/T 25498.1-2010
Weight 147g
IA3104 Contact Ultrasound Sensor
Peak Sensitivity >75 dB ISO 12714: 1999
Noise Floor <10 μVRMS(15 - 70 kHz)
Size 35 × 40 × 135 mm, not including waveguide
CRY5820 SonoDAQ Pro
lsolation 1000V
Channel 24 channels/Mainframe
Interface USB-C / 2 x GLAN / 2 x CAN FD / WIFI
OpenTest
Mode Measure Mode, Analysis Mode, Sequence Mode
Monitor Scope, FFT Spectrum, Spectrogram,RMS Level, DC Level, Peak Level, THD Ratio, THD+N Ratio, Crosstalk, etc.
Measure FFT Analysis, Octave Analysis, Continuous Sweep, Stepped Frequency Sweep, Sound Power Testing, Sound Level Meter, Sound Quality, etc.
CRY3408 Pressure-field Microphone, 1/4",Prepolarized high-level,0.14 mV/Pa
Field Type Pressure-field
Sensitivity 0.14 mV/Pa, -77±3 dB re 1V/Pa
Frequency Response 10 Hz to 20 kHz ±2 dB
CRY3408-S01 Pressure-field Prepolarized High-level Microphone Set, 1/4", 0.14mV/Pa
Field Type Pressure-field
Sensitivity 0.14 mV/Pa, -77±3 dB re 1V/Pa
Frequency Response 10 Hz to 20 kHz ±2 dB