    CRYSOUND Measurement Microphone Alternatives for B&K, GRAS and PCB Models

    Many acoustic laboratories, automotive NVH teams, consumer-electronics developers and third-party testing organizations already operate measurement systems built around HBK/Brüel & Kjær, GRAS or PCB Piezotronics products.

    When existing systems need more channels, replacement sensors, shorter procurement cycles or a complete platform update, engineers often ask a practical question: Which CRYSOUND products should be evaluated against the models already in use?

    The answer cannot be determined from capsule size or physical appearance alone. Two products may both be described as 1/2-inch measurement microphones while differing in sound-field response, polarization, sensitivity, frequency range, dynamic range, powering method or mechanical interface.

    This guide groups commonly used HBK/B&K, GRAS and PCB products by type and application, and provides corresponding CRYSOUND models as a starting point for system expansion, replacement and migration.

    Important: What Does "Alternative" Mean in This Guide?

    In this article, an alternative means a product with the same or a similar sound-field type, physical size, intended application or applicable standard that can be shortlisted for a new project or system migration.

    It does not mean that every listed model is a specification-for-specification duplicate or a drop-in replacement that can be installed without verification. Before approving a replacement, users should compare at least six areas:

    1. Sound-field type: free-field, pressure-field or random-incidence;
    2. Capsule size: 1 inch, 1/2 inch or 1/4 inch;
    3. Polarization and powering: prepolarized, externally polarized 200 V, or constant-current powered;
    4. Measurement range: sensitivity, frequency response, self-noise and maximum SPL;
    5. System compatibility: preamplifier, thread, connector, cable and DAQ input;
    6. Standards and calibration: applicable IEC requirements, calibration method and measurement uncertainty.

    Measurement microphones should be selected by combining sound-field type, size, frequency range, dynamic range and polarization rather than by comparing brand model numbers alone.

    1. Measurement Microphone Cartridge Cross-Reference

    The following table is intended for users who plan to replace a microphone cartridge while retaining an existing preamplifier, or who are redesigning the complete measurement chain. Some competitor models are externally polarized, while their CRYSOUND application alternatives may be prepolarized. These should therefore be treated as comparable products for the same measurement task rather than automatic drop-in replacements.

    TypeHBK / B&K ModelsGRAS ModelsPCB ModelsComparable CRYSOUND Models
    1-inch free-field microphone4145, externally polarized--CRY3101, CRY3103*, prepolarized
    1-inch pressure-field microphone4144, externally polarized40EN, externally polarized377A15CRY3102, prepolarized
    1/2-inch free-field, externally polarized4190, 4191, 419340AC, 40AF377C41CRY3281, CRY3285
    1/2-inch free-field, prepolarized4189, 496640AE, 40AM377A06, 377B02CRY3201, CRY3203
    1/2-inch random-incidence, prepolarized494240AQ377A21CRY3206*
    1/2-inch pressure-field, externally polarized419240AG, 40AP-CRY3282, CRY3284
    1/2-inch pressure-field, prepolarized4953, 4956, 497140AD, 40AO377B11CRY3202, CRY3204, CRY3212*
    1/4-inch free-field, externally polarized493940BF-CRY3485
    1/4-inch free-field, prepolarized494540BE377C01CRY3401, CRY3403
    1/4-inch pressure-field, externally polarized493840BP-CRY3482
    1/4-inch pressure-field, prepolarized494440BD377C10CRY3402, CRY3406
    1/4-inch high-pressure microphone4941, externally polarized40BH, externally polarized377A12, externally polarizedCRY3484*, externally polarized; CRY3404 and CRY3408, prepolarized

    How Should Multiple CRYSOUND Options Be Narrowed Down?

    When several CRYSOUND models appear in the same row, the products normally have different priorities in sensitivity, frequency range, self-noise or maximum SPL.

    • Higher sensitivity is normally preferred for low-level measurements in the standard audio range.
    • Lower sensitivity normally provides more headroom for high-SPL measurement.
    • Wider frequency response is useful for high-frequency noise, ultrasound and broadband NVH work.
    • Lower self-noise is important when testing quiet appliances, fans, headphones and precision motors.

    CRYSOUND offers 1-inch, 1/2-inch and 1/4-inch microphone cartridges for free-field, pressure-field and random-incidence applications, with multiple polarization, sensitivity and frequency-range configurations.

    2. Measurement Microphone Set Cross-Reference

    A microphone set normally combines the microphone cartridge, preamplifier and connecting cable. For users connecting the sensor directly to an existing data acquisition system, selecting a complete set is often simpler than replacing only the cartridge because it reduces the risk of mechanical, electrical and noise-performance mismatch.

    IEPE, CCP and CCLD are commonly used manufacturer terms for constant-current-powered measurement chains. However, supply current, compliance voltage, connector type, TEDS support and input range must still be checked before connection.

    TypeHBK / B&K ModelsGRAS ModelsPCB ModelsComparable CRYSOUND Models
    1-inch free-field set, IEPE/CCP/CCLD---CRY3101-S01
    1-inch pressure-field set, IEPE/CCP/CCLD---CRY3102-S01
    1/2-inch free-field set, IEPE/CCP/CCLD4188-A-021, 4188-C-001, 4188-L-001, 4189-A-021, 4189-W-003, 4189-H-041, 4966-A-041, 4966-H-04146AE, 46AK, 46AM, 46AZ, 146AE, 246AE378A06, 378B02CRY3201-S01, CRY3203-S01, CRY3203-S02, CRY3213
    1/2-inch free-field set, externally polarized 200 V4190-B-001, 4190-C-001, 4190-L-001, 4191-B-001, 4191-L-001, 4193-B-004, 4193-C-004, 4193-L-00446AC, 46AF-CRY3281-S01*, CRY3285-S01*
    1/2-inch low-noise microphone set4955, 4955-A, 200 V47HC, CCP378A04, IEPECRY3261-S02, IEPE
    1/2-inch pressure-field set, IEPE/CCP/CCLD4956-W-001, 4971-H-04146AD, 46AO, 46AO-S2378B11, 378C13CRY3202-S01, CRY3202-S02, CRY3204-S01
    1/2-inch pressure-field set, externally polarized 200 V4192-B-001, 4192-C-001, 4192-L-00146AG, 46AP-CRY3282-S01*
    1/2-inch random-incidence set4942-A-021, 4942-A-031, 4942-C-001, 4942-H-041; 4943-B-001 and 4943-C-001, 200 V46AQ, CCP; 46AR, 200 V378C20, 378A21CRY3206-S01*, IEPE
    1/4-inch free-field set, IEPE/CCP/CCLD4954-A, 4954-A-011, 4954-A-023, 4954-B, 4954-W-00446BE, 46BC378C01, 378A08CRY3401-S01, CRY3401-S02*, CRY3403-S01, CRY3403-S02
    1/4-inch free-field set, externally polarized 200 V4939-A-011, 4939-C-002, 4939-L-00246BF-1, 46AN-CRY3485-S01*
    1/4-inch pressure-field set, IEPE/CCP/CCLD4944-A, 4944-B, 4944-W-007, 4989-A, 4989-A-00146BD, 46BD-S1, 46BL-1, 46BL-1-FV378C10, 378A14CRY3402-S01, CRY3402-S02, CRY3402R-S02*, CRY3406-S01
    1/4-inch pressure-field set, externally polarized 200 V4938-A-011, 4938-D-011, 4938-L-00246BP-1-CRY3482-S01
    1/4-inch high-pressure microphone set4941-A-011, 4941-C-002, 200 V46BG and 46BF-FV, CCP; 46BH, 200 V378A12CRY3404-S01 and CRY3408-S01, IEPE; CRY3484-S01*, 200 V

    3. Ear Simulator and Coupler Cross-Reference

    Ear simulator and coupler selection should begin with the applicable standard and the type of device under test. Products within the IEC 60318 series may be intended for circumaural headphones, supra-aural headphones, insert earphones, hearing aids or extended high-frequency devices. Mechanical dimensions, acoustic impedance, cavity volume, built-in microphone and calibration data must also be reviewed.

    Standard or ApplicationHBK / B&K ModelsGRAS ModelsPCB ModelsComparable CRYSOUND Models
    IEC 60318-1 ear simulator for supra-aural or circumaural headphones4153, 418543AA, 43AD, RA0039AEC201-ACRY3718
    IEC 60318-4 occluded-ear simulator for insert earphones415743AC, 43AC-S1, RA0045, RA0045-S1AEC304CRY3711
    IEC 60318-4 extended high-frequency or Hi-Res ear simulator-43AC-S4, 43AC-S5, 43AC-S6, RA0401, RA0402, RA0403-CRY3713*, CRY716*
    IEC 60318-4 low-noise ear simulator-43BB-CRY3721, CRY3722*
    IEC 60318-3 / NBS 9-A 6 cc coupler415243AF, RA0075AEC100CRY3717
    IEC 60318-5 2 cc coupler for hearing aids or insert earphones494643AB, RA0038AEC202, AEC203CRY3719
    IEC 60318-8 0.4 cc high-frequency coupler-RA0252, 43BA-1, 43BA-2, 43BA-3-CRY886*

    4. Mouth Simulator Cross-Reference

    Mouth simulators reproduce the acoustic field around the human mouth and are widely used for testing telephones, communication terminals, microphones, headsets and voice-enabled devices. In addition to frequency range and output SPL, users should compare the measurement reference point, equalization method, distortion, amplifier requirements and fixture dimensions.

    TypeHBK / B&K ModelsGRAS ModelsPCB ModelsComparable CRYSOUND Models
    Standard mouth simulator4227, 4227-A44AA, 44AB-CRY3602, CRY3605
    Extended high-frequency mouth simulator---CRY3603

    CRY3602 and CRY3605 support conventional communication and microphone testing, while CRY3603 is designed for wider-band, high-frequency acoustic testing.

    5. How Can You Determine Whether a Product Is a Drop-In Replacement?

    Scenario 1: Replacing the Microphone Cartridge Only

    When the existing preamplifier will be retained, confirm:

    • Whether the microphones have the same sound-field response;
    • Whether the microphone is prepolarized or externally polarized;
    • The mechanical thread and electrical contact arrangement;
    • Whether the sensitivity fits the current DAQ input range;
    • Whether the dynamic range meets the application requirements.

    Changing from an externally polarized microphone to a prepolarized microphone is normally not a cartridge-only replacement. The preamplifier or signal-conditioning configuration will usually need to change as well.

    Scenario 2: Replacing the Complete Microphone Set

    When a complete CRYSOUND microphone set is used, the primary checks are:

    • Availability of the correct IEPE constant-current supply;
    • BNC, SMB, Microdot, Lemo, or other connector format;
    • IEPE current, compliance voltage and input headroom;
    • TEDS requirements;
    • Cable length and operating environment.

    For new systems or large channel expansions, complete sets often make calibration, cabling and spare-parts management easier to standardize.

    Scenario 3: Migrating a Multi-Channel System

    For sound power, automotive NVH, wind-tunnel, acoustic-array or production-line systems, replacing every channel at once is not recommended. A more controlled process is to select four to eight channels for an A/B validation using the same sound source, microphone position, cables, sampling configuration and analysis software.

    • 250Hz/ Sensitivity at 1 kHz;
    • Frequency response;
    • System noise floor;
    • Phase consistency;
    • Distortion and overload recovery at high SPL;
    • Calibration repeatability.

    Once the results meet the project acceptance criteria, the replacement can be expanded in stages.

    6. Why Evaluate CRYSOUND During a Replacement Project?

    Broad Product Coverage

    The CRYSOUND sensor portfolio includes measurement microphone cartridges, complete microphone sets, preamplifiers, ear simulators, couplers and mouth simulators for environmental noise, automotive NVH, sound power, electroacoustic, low-noise and high-frequency testing.

    Prepolarized and Externally Polarized Options

    Users can select IEPE prepolarized sets for modern constant-current-powered measurement systems or 200 V externally polarized products for traditional laboratory measurement chains.

    Complete Sets and Individual Cartridges

    Users retaining an existing preamplifier can evaluate individual microphone cartridges, while new systems can use matched microphone and preamplifier sets.

    Calibration and Long-Term Support

    CRYSOUND measurement microphones are supplied with individual calibration information, supporting channel records, periodic calibration and long-term measurement programs. Refer to the latest official policies for current calibration and warranty coverage.

    Frequently Asked Questions

    Can I install a listed CRYSOUND model and continue using the previous calibration value?

    No. After changing a microphone cartridge, preamplifier or complete set, the new calibration sensitivity must be entered into the measurement system. Field calibration or laboratory calibration should then be performed according to the project requirements.

    Does compliance with the same IEC standard mean that two products are identical?

    No. A common standard establishes shared baseline requirements, but sensitivity, self-noise, frequency range, maximum SPL, environmental limits and mechanical interfaces may still differ.

    Are IEPE, CCP and CCLD completely interchangeable?

    These terms generally describe constant-current-powered sensor interface families. However, supply current, compliance voltage, connector type, input range and TEDS support may differ between systems. Both the microphone set and DAQ specifications should be reviewed.

    Should I select an individual cartridge or a complete microphone set?

    An individual cartridge may be suitable when the existing preamplifier will be retained. A complete set is normally preferable for a new system, a large channel expansion or a project where compatibility risk needs to be minimized.

    What information is needed for a more precise recommendation?

    Provide the existing brand and complete model number, sound-field application, required frequency and SPL ranges, preamplifier and DAQ models, connector and powering method, applicable standards and calibration requirements.

    Conclusion

    A model cross-reference can quickly create a shortlist when moving from HBK/B&K, GRAS or PCB products to CRYSOUND, but the final selection should be based on the complete measurement chain rather than capsule diameter or product appearance alone.

    Define the application and standard → match the sound-field type and size → verify polarization and interface → compare critical performance → complete A/B validation and recalibration.

    For assistance expanding an existing system, replacing microphones approaching the end of their service life, or evaluating CRYSOUND alternatives for current HBK/B&K, GRAS or PCB equipment, send us the existing model numbers and measurement requirements. The CRYSOUND team can support model selection, interface verification and practical validation. Contact us by submitting the following form.

    Guide to Common Measurement Microphone Interfaces

    How a 10-Year Warranty Lowers Measurement Microphone Costs

    What Is a Measurement Microphone? Complete Guide to Types, Selection & Applications

    Get in touch

    If you are interested or have questions about our products, book a demo and we will be glad to show how it works, which solutions it can take part of and discuss how it might fit your needs and organization.

    Downloads Downloads
    Quote 0
    Quote
    +86-571-88225128 +86-571-88225128
    Experience Demo Experience Demo
    Ask an Expert Ask an Expert