Large Tripod - Soundking S08 Microphone Tripod

Large Tripod - Soundking S08 Microphone Tripod

Downloads
Product Highlights
Technical Specifications
Main Features

Related Products

Microphone Sound Fields: Free, Pressure & Diffuse Guide

In acoustic measurements (SPL, frequency response, noise, reverberation, etc.), large errors often come not from instrument accuracy, but from a mismatch between the assumed sound field and the actual one. What a microphone reads as sound pressure is not strictly equivalent across different fields-especially at mid and high frequencies, where the microphone dimensions become comparable [...]

Microphone Test System

CRYSOUND provides a microphone test system test system solution.

Differences Between Measurement Microphones and Regular Microphones

Across acoustics testing, product R&D, environmental noise monitoring, and NVH analysis, simply "capturing sound" isn't the goal-accurate sound measurement is. A measurement microphone is engineered for repeatable, traceable, and quantifiable results, so your data stays comparable across devices, labs, and time. In this post, we explain what a measurement microphone is and how it differs [...]

CRYSOUND Measurement Microphone Alternatives for B&K, GRAS and PCB Models

Many acoustic laboratories, automotive NVH teams, consumer-electronics developers and third-party testing organizations already operate measurement systems built around HBK/Brüel & Kjær, GRAS or PCB Piezotronics products. When existing systems need more channels, replacement sensors, shorter procurement cycles or a complete platform update, engineers often ask a practical question: Which CRYSOUND products should be evaluated against [...]

Guide to Common Measurement Microphone Interfaces

From the outside, a measurement microphone looks deceptively simple. But in real-world engineering, its interface options are surprisingly diverse: Lemo, BNC, Microdot, 10-32 UNF, M5, SMB... Many newcomers to acoustics ask questions like: This article provides a structured overview of common measurement microphone interfaces, looking at physical connectors, powering methods, cable characteristics, and typical application-driven [...]

How a 10-Year Warranty Lowers Measurement Microphone Costs

As the core component of measurement chains, the long-term stability of measuring microphones directly impacts the comparability and traceability of measurement data. The 10-year limited warranty (hereinafter referred to as the 10-year warranty) is not merely a service commitment, but a comprehensive capability demonstrated through manufacturing consistency control, reliability verification systems, and traceable evidence chains. [...]

Sound Calibrator Explains Measurement Microphone Calibration

In day-to-day acoustic measurements, it's common to hear: "Insert the measurement microphone into the calibrator, press the button, and the microphone is calibrated." From an engineering and metrology perspective, that wording is an oversimplification. To place a sound calibrator correctly in the measurement chain, we should start with what it generates-and what it can (and [...]
CRY5820 SonoDAQ Pro and CRY3203-S01 TEDS measurement microphone set for reliable multichannel acoustic setup

TEDS Microphones: Faster, More Reliable Multichannel Setup

In multichannel acoustic testing, entering microphone model numbers, sensitivities, and calibration data one channel at a time is slow and prone to error. TEDS allows a data acquisition system to read key parameters stored in a microphone or preamplifier, helping engineers configure channels faster and maintain consistent test settings. This article tests the CRYSOUND CRY3203-S01 [...]
CRY3402, CRY3404, and CRY3408 high-SPL microphones are shown in the foreground with a rocket launch in the background, illustrating aerospace acoustic measurement under extreme sound pressure levels.
High SPL Measurement

Working Standard Microphone Guide for High SPL Testing: Distortion, Test Environment, and Selection

Learn how to select a working standard microphone for high SPL testing above 160 dB, including distortion limits, test environment requirements, THD data, and CRYSOUND microphone options.

Why Measurement Microphones Are Made in Cleanrooms

Measurement microphones are used in acoustic metrology, type-approval testing, and engineering measurements. Unlike general audio capture applications, measurement scenarios place far greater emphasis on consistency and traceability: the same microphone should deliver stable output when re-tested over time; variation within a production lot should be sufficiently small; and performance fluctuations between lots should remain controllable. [...]

Get in touch

If you are interested or have questions about our products, book a demo and we will be glad to show how it works, which solutions it can take part of and discuss how it might fit your needs and organization.

Downloads Downloads
Quote 0
Quote
+86-571-88225128 +86-571-88225128
Experience Demo Experience Demo
Ask an Expert Ask an Expert