1/1
CRY321-S01 Free-field, Prepolarized Microphone Set ,1/2",25mV/Pa
CRY321-S01 is a free-field pre-polarized measurement microphone kit specifically developed for noise testing requirements.
The unique design of CRY321-S01 enables it to deliver precise and reliable acoustic measurement results, making it widely applicable in environmental fields such as sound level meter testing and noise monitoring.
Downloads
Product Highlights
CRY321-S01 Measurement Microphone Set Typical Frequency Response
The graph (right) shows the frequency response curves for 0° incidence in a free-field environment and the frequency response curves obtained using the electrostatic excitation method.
Technical Specifications
Field Type
Free-field
Sensitivity
25 mV/Pa, -32 dB re 1 V/Pa
Frequency Response
10 Hz to 12.5 kHz ±2 dB
Polarization Voltage
0 V
Dynamic Range(re.20uPa)
22 dB to 138 dB
Operating Temperature
-20℃ to +60℃ (-4℉ to +140℉)
Temperature Stability
-0.01 dB/℃ (-10℃ to +50℃) -0.006 dB/℉ (+14℉ to +122℉)
Static Pressure Stability
-0.01 dB/kPa
Operating Humidity Range
0 to 90%RH no condensation
Humidity Stability
< 0.1 dB (0 to 90%RH no condensation)
Pressure Equalization Vent
Rear vented
IEC 61094-4 Type
WS2F
Output Impedance
< 50 Ω
Maximum Output Voltage
>8.0 Vp
Power Supply
IEPE (2 to 20)mA, Typical: 4 mA
Interface Type
BNC
Height with Grid
70.2 mm (2.76" )
Diameter with Grid
13.2 mm (0.52" )
Main Features
- Use of Free-field Microphones
- TEDS Microphone Set
- IEC 61094 4:1995 Measurement microphones - Part 4
Related Products
CRY3213 NVH Measurement Microphone
Field Type
Free-field
Sensitivity
50 mV/Pa, -26±2 dB re 1V/Pa
Frequency Response
3.15 Hz-20 kHz ±2 dB
CRY3201-S01 Free-Field Microphone Set, 1/2", 12.5mV/Pa
Field Type
Free-field
Sensitivity
12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 40kHz±2dB
CRY3103 Free-field Microphone, 1", Prepolarized, 100 mV/Pa
Field Type
Free-field
Sensitivity
100 mV/Pa, -20 dB±2 dB re 1 V/Pa
Frequency Response
4 Hz to 12 kHz ±2 dB
CRY3203 Free-field Microphone, 1/2", Prepolarized, 50mV/Pa
Field Type
Free-field
Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 20kHz±2dB
CRY3203-S01 Free-Field Microphone Set, 1/2", 50mV/Pa
Field Type
Free-field
Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 20kHz±2dB
In acoustic measurements (SPL, frequency response, noise, reverberation, etc.), large errors often come not from instrument accuracy, but from a mismatch between the assumed sound field and the actual one. What a microphone reads as sound pressure is not strictly equivalent across different fields-especially at mid and high frequencies, where the microphone dimensions become comparable [...]
Across acoustics testing, product R&D, environmental noise monitoring, and NVH analysis, simply "capturing sound" isn't the goal-accurate sound measurement is. A measurement microphone is engineered for repeatable, traceable, and quantifiable results, so your data stays comparable across devices, labs, and time. In this post, we explain what a measurement microphone is and how it differs [...]
Many acoustic laboratories, automotive NVH teams, consumer-electronics developers and third-party testing organizations already operate measurement systems built around HBK/Brüel & Kjær, GRAS or PCB Piezotronics products. When existing systems need more channels, replacement sensors, shorter procurement cycles or a complete platform update, engineers often ask a practical question: Which CRYSOUND products should be evaluated against [...]
Get in touch